GERERAL OPERATING CHARACTERISTICS
Parameter | Symbol | Min. | Typ | Max. | Unit | Note |
Data Rate | Ethernet |
|
| 10.3125 |
| Gb/s |
|
Fiber Channel |
|
| 10.518 |
|
|
Supply Voltage | Vcc | 3.13 | 3.3 | 3.47 | V |
|
Vcc |
|
|
| V |
|
Supply Current | Icc5 |
|
|
| mA |
|
Icc3 |
|
| 300 | mA |
|
Operating Case Temp. | Tc | 0 |
| 70 | °C |
|
ELECTRICAL INPUT/OUTPUT CHARACTERISTICS
l Transmitter
Parameter | Symbol | Min. | Typ | Max. | Unit | Note |
Diff. input voltage swing |
| 120 |
| 820 | mVpp | 1 |
Tx Disable input | H | VIH | 2.0 |
| Vcc+0.3 | V |
|
L | VIL | 0 |
| 0.8 |
Tx Fault output | H | VOH | 2.0 |
| Vcc+0.3 | V | 2 |
L | VOL | 0 |
| 0.8 |
Input Diff. Impedance | Zin |
| 100 |
| Ω |
|
l Receiver
Parameter | Symbol | Min. | Typ | Max. | Unit | Note |
Diff. output voltage swing |
| 340 | 650 | 800 | mVpp | 3 |
Rx LOS Output | H | VOH | 2.0 |
| Vcc+0.3 | V | 2 |
L | VOL | 0 |
| 0.8 |
|
Note 1) TD+/- are internally AC coupled with 100Ω differential termination inside the module.
Note 2) Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
Note 3) RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user SERDES.
OPTICAL CHARACTERISTICS
l Transmitter
Parameter | Symbol | Min. | Typ | Max. | Unit | Note |
Operating Wavelength |
| 1290 |
| 1330 | nm |
|
Ave. output power (Enabled) | Po | -6 |
| 0 | dBm | 1 |
Extinction Ratio | ER | 4 |
|
| dB | 1 |
RMS spectral width | Δλ |
|
| 1 | nm |
|
Rise/Fall time (20%~80%) | Tr/Tf |
|
| 50 | ps | 2 |
Optical modulation amplitude | OMA | -6.2 |
|
| dBm |
|
Dispersion penalty |
|
|
| 1 | dB |
|
Output Optical Eye | Compliant with IEEE 0802.3ae |
l Receiver
Parameter | Symbol | Min. | Typ | Max. | Unit | Note |
Operating Wavelength |
| 1290 | 1310 | 1330 | nm |
|
Sensitivity | Psen |
|
| -14.4 | dBm | 3 |
Min. overload | Pimax | 0.5 |
|
| dBm |
|
LOS Assert | Pa | -30 |
|
| dBm |
|
LOS De-assert | Pd |
|
| -16 | dBm |
|
LOS Hysteresis | Pd-Pa | 0.5 |
| 4 | dB |
|
Note 1) Measured at 10.3125b/s with PRBS 231 – 1 NRZ test pattern.
Note 2) 20%~80%
Note 3) Under the ER worst case, measured at 10.3125 Gb/s with PRBS 231 - 1 NRZ test pattern for BER < 1x10-12